Photo gallery for the Vötsch/Beatronic EMC chambers.

Beatronic offers to modify the chambers with an advanced EMC shielding. The first model modified was the VT 4002 which become model VT 4002EMC.

This version (1.00) was developed in cooperation with Nokia Mobile Phones in Denmark and the latest revision are currently supplied to 3 different mobile phone producers in more than 8 different countries around the world.

Also manufactures of wireless access points, car alarms, hearing aid, GPS systems, computer motherboard and similar product developer, has purchased the now famous VT 4002EMC test chamber.

The patent pending EMC shielding technique, developed especial for temperature and  climatic test chambers, has allowed us to produce a considerable numbers units of this type, over a period of only 3 years.

It is a niche market but all producers of radio wave electronics, potential needs to shut out the surrounding EMI noise and measure the sensitivity at different temperatures.

The solution with a EMC-box inside the test space are serious compromising the chambers thermal performance.

Alternative; to fit the temperature test chamber, instruments and operator in a big EMC cage, is not very flexible.

The test chamber with EMC sealing incorporated in the test space walls, seams to be the best solution for most users.

In 2006 we also sealed a 340 litre test chamber with our EMC shielding technique, with great success and delivered finished product to a customer in China.

Here the VT 4034EMC is undergoing the final EMC damping measurements.

VT 4002EMCs under production.

Each unit will be submitted to a full functions test and re-calibration before shipment.

We can implement the EMC seal both into used (RETROFIT) and new equipment, with equal good result. It is, however, recommended that used chamber are in good condition, with a perfect operation record and not much older than 2-3 years.

The concept is constantly undergoing further development and improvements to increase the EMC damping. Every time an change are introduced, the unit will undergo a full EMC test according to the norm NT ELEC 030 from 1997.

Recently the VT 4002 EMC has been tested from 0,5 up to 6 GHz with good results, almost 57dB damping on average and more than 75 dB in the 800-1000 Mhz area.

The entry module allows the user to supply the DUT with power and at the same time extract measuring result from the shielded space. The module are exchangeable and can be manufactured to customer specifications.

This module is a "standard ver. 1.XX" module

Blank entry module allowing the end-user to do his own connections

VT 4002EMC version 2, with entry modules in both left and right side of the test space.

The module here holds 6 x 9 pole D-subs and 12 DC lead trough in one side and 6 x 24 SMAs on the other side.

The modules are interchangeable and can switched or changed to other versions.

Another special entry module. The SMA are the largest contributor to the thermal leak in the test chamber. It is always a good idea to reduce the numbers of connections and thereby increase the change rate and overall performance of the EMC chamber.

 

 

 

 

 

 

 

 

 

 

 

Download the data leaflet in our download section.